A Purchaser's Checklist for Boiler Retubing Enquiries
When a boiler is retubed, the tube order is usually on the critical path of a planned outage. Incomplete enquiries lead to wrong-spec quotes, re-quotes and late deliveries. This checklist lists the information Dinesh Tube India needs to quote boiler tubes for a retubing job accurately and quickly: which tube specification, which sizes, how many, which documents and by when.

Who This Checklist Is For
This page is for maintenance engineers, purchase teams and repair contractors collecting information for a tube supply quote. It is not boiler design or repair advice. The tube specification, wall thickness and any change of material must come from the boiler maker's drawings, the plant's engineers and the applicable boiler code and inspection authority. We quote and supply tubes to the specification you give us.
1. Boiler and Duty Data
2. Tube Specification and Grade
Send the specification and grade exactly as shown on the original drawing, data sheet or mill certificate. Common boiler-tube specifications include:
Important: replacement tubes should match the original specification and grade. A substitute (for example SA210 A1 in place of SA192) should only be quoted when the boiler designer or inspecting authority has approved it. Tell us if an approved alternative exists.
3. Dimensions, Lengths and Bends
4. Quantities and Spares
5. Documents, Certification and Inspection
6. Delivery and Outage Planning
Printable Boiler Retubing Enquiry Checklist
Print this checklist and fill it in, or copy the items into your enquiry email.
Ready to send your enquiry? Email the completed checklist, drawings and photos to kamlesh@dineshtube-india.com or call +91 83559 10913. You can also send an enquiry.
Boiler Retubing Enquiry: FAQs
What information is needed to quote boiler tubes for retubing?
The tube specification and grade, outside diameter, wall thickness (stating minimum or average wall), lengths or bend drawing, end preparation, quantity per circuit plus spares, required certificates and inspection, and the date the tubes must be on site.
Should I order boiler tubes by minimum wall or average wall?
Boiler tubes to ASME SA192, SA210 and SA213 are normally ordered by minimum wall thickness. Always state which basis your drawing uses, because a minimum-wall tube is thicker on average than an average-wall tube of the same nominal size.
Can SA210 tubes replace SA192 tubes?
Only if the boiler designer or inspecting authority approves the substitution. SA210 A1 has higher strength than SA192, but replacement tubes should normally match the original specification shown on the boiler drawings.
Do you supply boiler tubes with IBR or third-party inspection?
Tubes can be supplied with EN 10204 3.1 certificates as standard, and with 3.2 certificates, code documentation required by the boiler's inspecting authority, or third-party inspection on request. State these requirements in your enquiry.
How early should I send a boiler retubing enquiry?
As early as possible before the planned outage, ideally as soon as the scope is known. Common sizes may be available from stock, but special grades, long lengths, bends and third-party inspection add lead time.
Does Dinesh Tube India provide boiler retubing design or installation?
No. We supply boiler tubes to the specification you provide. Tube selection, repair design and installation are the responsibility of the boiler maker, plant engineers and repair contractor under the applicable boiler code.