A Tube Schedule Worksheet for Heat Exchanger Bundles
To quote tubes for a heat exchanger bundle we need the tube specification, OD, minimum wall, the number of tubes or U-bends, the cut length or U-bend radius and leg length for every row, the tests and documents, and the delivery date. This page turns that into a checklist and a printable tube schedule you can fill in from the bundle drawing or by measuring the old bundle.
Dinesh Tube India supplies heat exchanger tubes straight, cut to length, or U-bent, with stress relief of the bends on request. Common grades include SA179 and SA214 carbon steel, stainless, duplex, cupro-nickel and titanium tubes.

Who This Checklist Is For
This page is for maintenance engineers, purchase teams and exchanger fabricators collecting information for a tube supply quote, whether for a new bundle or for retubing an existing one. It is not exchanger design advice. The tube specification, wall thickness, bend radii and heat treatment must come from the exchanger data sheet, the designer and the applicable code (for example ASME Section VIII and TEMA). We quote and supply tubes to the schedule you give us.
1. Straight or U-Tube Bundle?
2. Counting the Tubes
3. Tube Specification and Grade
Send the specification and grade exactly as on the exchanger data sheet or the original mill certificate. Common heat exchanger tube specifications:
4. OD, Minimum Wall and Wall at the Bend
t0 = minimum wall before bending; t1 = minimum wall required by the design code for a straight tube; d0 = tube OD; R = mean bend radius. The tightest-radius row governs. Example: 19.05 mm OD, t1 = 1.65 mm, R = 38.1 mm gives t0 = 1.65 × (1 + 19.05 / 152.4) = 1.86 mm, so a 14 BWG (2.11 mm) minimum-wall tube would be ordered. Your exchanger designer should confirm the value.
5. Lengths, U-Bend Radii and Tolerances
6. Heat Treatment, Tests and Documents
Worked Example: U-Tube Bundle Tube Schedule
Illustrative example only, not a customer order. A U-tube bundle in SA179, 19.05 mm OD × 2.11 mm (14 BWG) minimum wall, with 120 tube holes (60 U-tubes) in 6 rows of 10, a 6,000 mm leg length and 25.4 mm tube pitch:
Developed length = 2 × leg length + π × mean radius. Total: 60 U-tubes, about 739 m of tube before spares. A complete enquiry for this bundle would also state stress relief of the bends (if required), the test, EN 10204 3.1 certificate, packing and delivery date.
Printable Tube Schedule and Checklist
Print this page and fill in the tube schedule and checklist, or copy them into your enquiry email.
Tube schedule (blank, to fill in): use one row per U-bend radius for a U-tube bundle, or one row per cut length for a straight-tube bundle. The first row, in grey, shows how to fill it in.
Ready to send your tube schedule? Email the completed worksheet and drawing to kamlesh@dineshtube-india.com, call or WhatsApp +91 83559 10913, or send an enquiry. Retubing a boiler instead? Use our boiler retubing enquiry checklist.
Heat Exchanger Tube Bundle RFQ: FAQs
What information is needed to quote heat exchanger tubes for a bundle?
The tube specification and grade, tube OD, wall thickness stating minimum or average wall, the bundle type (straight or U-tube), the number of tubes or U-bends, straight cut lengths or a U-bend schedule with radius and leg length per row, heat treatment of bends if required, tests, inspection documents and the required delivery date.
How do I count the tubes in a U-tube bundle?
Count the complete U-bends, not the holes in the tubesheet. Each U-bend uses two tubesheet holes, so a tubesheet with 120 tube holes takes 60 U-tubes. Then group the U-bends by row, because every row has a different bend radius and therefore a different tube length.
What wall thickness should I order for U-bent tubes?
The tube wall thins on the outside of the bend. TEMA RCB-2.33 gives the minimum wall to order before bending as t0 = t1 (1 + d0 / 4R), where t1 is the minimum wall required by the design code, d0 the tube OD and R the mean bend radius. The tightest radius row governs. Your exchanger designer should confirm the value.
Do you supply U-bent tubes with stress relief of the bends?
Yes. We supply U-bent heat exchanger tubes and can arrange stress relief or other heat treatment of the bends when the purchase order asks for it. State the radius range to be heat treated, the extent beyond the tangent point and the required temperature or standard.
Which straightness and length tolerances apply to heat exchanger tubes?
Straight tubes follow the general requirements specification for the tube grade, such as ASTM A450 for carbon and alloy steel or ASTM A1016 for stainless steel, unless your order states tighter limits. For U-tubes, state the leg-length, radius and ovality (flattening) limits from your data sheet or purchase specification in the enquiry.
Does Dinesh Tube India design or fabricate tube bundles?
No. We supply the tubes, straight or U-bent, to the specification and schedule you provide. Bundle design, tube-to-tubesheet joints, retubing and installation are the responsibility of the exchanger designer, fabricator or repair contractor.