ASME SA192 / ASTM A192 Specification Summary
This page summarises the requirements of ASME SA192 / ASTM A192, Seamless Carbon Steel Boiler Tubes for High-Pressure Service. ASME SA192 is identical to ASTM A192 and is used for ASME and IBR boiler work. Always check the edition named in your purchase order.
To buy tubes, see our ASTM A192 carbon steel tubes page. A printable version is available as the ASTM A192 tube specification sheet (PDF).
Scope of SA192
| Item | Requirement |
|---|---|
| Title | Seamless carbon steel boiler tubes for high-pressure service |
| Product | Minimum-wall-thickness seamless boiler and superheater tubes |
| Sizes usually furnished | 1/2 in to 7 in (12.7 to 177.8 mm) OD; 0.085 to 1.000 in (2.2 to 25.4 mm) minimum wall |
| Other sizes | May be furnished if they meet all other requirements of the specification |
| General requirements | ASTM A450 / ASME SA450 |
| Units | Inch-pound unless the A192M (SI) designation is ordered |

Manufacture and Heat Treatment
SA192 Chemical Composition (%)
Supplying an alloy grade that requires the addition of elements not listed is not permitted. Product analysis is made only when requested on the order (one tube per 100 pieces over 76.2 mm OD, one per 250 pieces at 76.2 mm and under, or one per heat).
Hardness and Design Properties
Many supplier pages list tensile values as test requirements. In A192 the mandatory mechanical limit is hardness, together with the flattening, flaring and pressure tests below.
Dimensional Tolerances (ASTM A450)
Outside diameter
Minimum wall thickness
Values from ASTM A450; check the edition on your order. Thin-wall tubes may show additional ovality as allowed by A450.
Required Tests
A lot is defined in the specification by size, heat and heat-treatment furnace. Supplementary requirements and IBR (Form III-B) certification can be added by agreement.
Related Tube Grades
Ordering Information
An SA192 order should state: quantity; name of material (seamless tubes); manufacture (hot finished or cold finished); size (OD and minimum wall); length (specific or random); hydrostatic or non-destructive test; certificates (EN 10204 3.1, IBR Form III-B or as required); and any supplementary requirements.
Need SA192 tubes? Send your OD, minimum wall, length and quantity to kamlesh@dineshtube-india.com or call +91 83559 10913, or see the A192 tubes product page.
SA192 Specification: FAQs
What does the SA192 specification cover?
ASME SA192 (identical to ASTM A192) covers minimum-wall-thickness, seamless carbon steel boiler and superheater tubes for high-pressure service. Sizes usually furnished are 1/2 in to 7 in (12.7 to 177.8 mm) outside diameter and 0.085 to 1.000 in (2.2 to 25.4 mm) minimum wall; other sizes may be supplied if they meet all other requirements.
Does SA192 have a minimum tensile strength?
A192 does not require a tension test. Its mandatory mechanical limits are maximum hardness (137 HBW for walls 5.1 mm and over, 77 HRB for thinner walls) plus flattening, flaring and pressure tests. For design, ASME Section II-D uses 325 MPa (47 ksi) tensile and 180 MPa (26 ksi) yield for SA192.
Can SA192 tubes be hot finished?
Yes. SA192 tubes are seamless and may be hot finished or cold finished. Hot-finished tubes need not be heat treated; cold-finished tubes must be heat treated at 650 °C (1200 °F) or higher after the final cold finishing.
What is the difference between SA192 and SA179?
Both are seamless low-carbon steel tubes with the same carbon and manganese limits. SA192 is for high-pressure boiler and superheater tubes up to 7 in OD, adds a 0.25% silicon limit and allows 137 HBW / 77 HRB; SA179 is cold-drawn only, for heat exchangers and condensers up to 3 in OD, with 72 HRB maximum.
What is the difference between SA192 and SA210 A-1?
SA192 is a low-carbon (0.06–0.18% C) tube controlled by hardness. SA210 Grade A-1 is a medium-carbon (0.27% C max) seamless boiler tube with a mandatory tensile test (415 MPa tensile, 255 MPa yield), so it allows thinner walls for the same pressure.
How are SA192 tube tolerances specified?
Dimensional tolerances come from the general-requirements specification ASTM A450 / ASME SA450 and depend on whether the tube is hot finished or cold finished. Because SA192 is a minimum-wall specification, the wall may be over the ordered minimum but not under it.
This is a summary for reference only. ASTM A192/A192M and ASME SA-192 are copyrighted standards; the purchased standard and the edition on the order govern.