How to Turn a BWG Tube Size into an Order That Cannot Be Misread
A BWG number is only a wall thickness in inches (14 BWG = 0.083" = 2.11 mm). To order tubes correctly, give the outside diameter and the wall in mm, and say whether that wall is the minimum or the average wall, because the tolerance, the wall you receive, the inside diameter and the weight all depend on it.
Most re-quotes on heat exchanger tubes and boiler tubes come from an enquiry that gives a gauge without its basis, or mixes inch and metric sizes. This guide converts a typical enquiry step by step. For full size lists, see the SA179 tube sizes and SA214 tube sizes.

What Does “3/4" OD × 14 BWG” Actually Mean?
Minimum Wall or Average Wall: Which Does Your Specification Use?
If your drawing says only “14 BWG” and the specification is A179 or A214, the tube is ordered as 2.11 mm minimum wall. For stainless and alloy tubes, ask your designer which basis the calculation used before you place the order.
What Does the Tolerance Do to the Wall You Receive?
Check the edition of the specification named in your contract. Mills generally aim a little above the minimum, so a minimum-wall tube is typically delivered about 10% thicker than the figure ordered; that is why it weighs and costs more than an average-wall tube of the same nominal size.
Worked Enquiry: From Inch / BWG to an Order Line
Illustrative example
An enquiry arrives for “SA179 tubes, 3/4" × 14 BWG, 20 ft, 400 nos.” This is how we convert and confirm it before quoting.
Two checks follow from the table. The tube ID can be as small as about 13.99 mm, so a designer who used 14.83 mm in the thermal calculation should confirm the margin. And if the enquiry had been treated as 2.11 mm average wall, the wall could have been as thin as 1.90 mm, which does not meet a 2.11 mm minimum. To guarantee 2.11 mm on an average-wall basis you would need to order about 2.35 mm average, close to 13 BWG.
The confirmed order line becomes:
Buying Average Wall to Meet a Minimum Wall
Illustrative example
A stainless tube to ASTM A213 TP304L, 3/4" OD, needs a design minimum of 1.65 mm (16 BWG). Two ways to order it:
Average wall is only an option where the specification allows it, such as A213, A249 and A269. For A179 and A214 the order is always on minimum wall.
Common BWG and Wall Thickness Ordering Mistakes
BWG to mm and Inch Reference (8 to 22 BWG)
Birmingham (Stubs) wire gauge inch values, converted at 25.4 mm per inch and rounded to 0.01 mm. Typical use by gauge is shown in our heat exchanger tube BWG chart.
RFQ Line to Copy for Tube Wall Thickness
Replace the values with your own and keep every field:
Not sure which basis your drawing uses? Send the drawing or data sheet to kamlesh@dineshtube-india.com, call or WhatsApp +91 83559 10913, or send an enquiry. We confirm OD, wall and basis before we quote SA179, SA214, carbon steel, alloy steel or stainless steel tubes.
BWG and Minimum Wall: FAQs
What is 14 BWG in mm?
14 BWG is 0.083 inch, which is 2.11 mm (2.108 mm). The gauge is a wall thickness only, so 14 BWG is 2.11 mm whatever the tube outside diameter: a 3/4" (19.05 mm) or a 1" (25.4 mm) tube at 14 BWG both have a 2.11 mm wall.
Is a BWG wall thickness a minimum wall or an average wall?
Neither on its own. BWG only gives a thickness; the order must also say whether that thickness is the minimum or the average wall. ASTM A179, A214, A192, A210 and A556 tubes are ordered by minimum wall. ASTM A213, A249 and A269 stainless and alloy tubes can be ordered either way, so state which one you need.
Why are minimum-wall tubes heavier and more expensive?
A minimum-wall tube has a plus-only tolerance (for example +20% / −0 for cold-drawn seamless tubes up to 1-1/2" OD under ASTM A450), so the wall the mill delivers is above the figure you order, often about 10% above. Tubes are priced by weight, so the same nominal size costs more on a minimum-wall basis than on an average-wall basis.
Can I order average wall and still be sure of a minimum wall?
Yes, where the specification allows average wall. Divide the minimum wall you need by 0.9 (for a ±10% average-wall tolerance) and order that figure as average wall. For a 1.65 mm minimum, an average wall of 1.83 mm gives a delivered range of about 1.65 to 2.01 mm.
What is the difference between BWG and SWG?
They are two different gauge tables. Most numbers give a slightly different thickness: 14 BWG is 2.11 mm but 14 SWG is 2.03 mm, and 16 BWG is 1.65 mm but 16 SWG is 1.63 mm. Always state the gauge system, or better, give the wall in mm.
Is BWG used for pipe?
No. BWG is used for tubes, which are ordered by actual outside diameter and wall thickness. Pipe is ordered by nominal pipe size (NPS) and schedule, for example 3/4" NPS SCH 40, which is 26.7 mm OD with a 2.87 mm nominal wall. See our carbon steel pipes page for pipe.