ASME SA210 / ASTM A210 Specification Summary
This page summarises the requirements of ASME SA210 / ASTM A210, Seamless Medium-Carbon Steel Boiler and Superheater Tubes, for Grade A-1 and Grade C. ASME SA210 is identical to ASTM A210 and is used for ASME and IBR boiler work. Always check the edition named in your purchase order.
To buy tubes, see our ASME SA210 Gr A1 carbon steel tubes page. A printable version is available as the ASTM A210 tube specification sheet (PDF).
Scope of SA210
| Item | Requirement |
|---|---|
| Title | Seamless medium-carbon steel boiler and superheater tubes |
| Product | Minimum-wall-thickness seamless boiler tubes and boiler flues, including safe ends, arch and stay tubes, and superheater tubes |
| Grades | A-1 and C |
| Sizes usually furnished | 1/2 in to 5 in (12.7 to 127 mm) OD; 0.035 to 0.500 in (0.9 to 12.7 mm) minimum wall |
| Other sizes | May be furnished if they meet all other requirements; mechanical property requirements do not apply to tubing smaller than 1/8 in (3.2 mm) ID or 0.015 in (0.4 mm) wall |
| General requirements | ASTM A450 / ASME SA450 |
| Units | Inch-pound unless the A210M (SI) designation is ordered |

Manufacture and Heat Treatment
SA210 Chemical Composition (%)
For each 0.01% reduction below the specified carbon maximum, an increase of 0.06% manganese above the specified maximum is permitted, up to 1.35% Mn. Supplying a grade that requires the addition of elements not listed is not permitted.
SA210 Mechanical Properties
Elongation for thinner walls (longitudinal strip tests)
For walls under 8 mm (5/16 in), 1.50 percentage points are deducted from 30% for each 0.8 mm (1/32 in) decrease in wall thickness. For other thicknesses, E = 1.87t + 15.00 (t in mm) or E = 48t + 15.00 (t in inches).
Dimensional Tolerances (ASTM A450)
Outside diameter
Minimum wall thickness
Values from ASTM A450; check the edition on your order. Thin-wall tubes may show additional ovality as allowed by A450.
Required Tests
Supplementary requirements and IBR (Form III-B) certification can be added by agreement.
Related Tube Grades
Ordering Information
An SA210 order should state: quantity; name of material (seamless tubes); grade (A-1 or C); manufacture (hot finished or cold finished); size (OD and minimum wall); length (specific or random); optional requirements such as surface condition or a non-destructive test in place of the hydrostatic test; certificates (EN 10204 3.1, IBR Form III-B or as required); and any supplementary requirements.
Need SA210 tubes? Send your grade, OD, minimum wall, length and quantity to kamlesh@dineshtube-india.com or call +91 83559 10913, or see the SA210 A1 tubes product page.
SA210 Specification: FAQs
What does the SA210 specification cover?
ASME SA210 (identical to ASTM A210) covers minimum-wall-thickness, seamless medium-carbon steel boiler tubes and boiler flues, including safe ends, arch and stay tubes, and superheater tubes. It has two grades, A-1 and C. Sizes usually furnished are 1/2 in to 5 in (12.7 to 127 mm) OD and 0.035 to 0.500 in (0.9 to 12.7 mm) minimum wall.
What is the difference between SA210 Grade A-1 and Grade C?
Grade A-1 allows up to 0.27% carbon and 0.93% manganese and needs 415 MPa (60 ksi) tensile and 255 MPa (37 ksi) yield, with 143 HB / 79 HRB maximum hardness. Grade C allows up to 0.35% carbon and 0.29–1.06% manganese and needs 485 MPa (70 ksi) tensile and 275 MPa (40 ksi) yield, with 179 HB / 89 HRB maximum hardness.
Is SA210 tensile tested?
Yes. Unlike SA192, SA210 has mandatory tensile requirements: a tension test is made on each lot, in addition to flattening, flaring and hardness tests and a hydrostatic or non-destructive electric test on every tube.
Do SA210 tubes need heat treatment?
Hot-finished SA210 tubes need not be heat treated. Cold-finished tubes must be given a subcritical anneal, a full anneal or a normalizing heat treatment after the final cold finishing.
What is the difference between SA210 A-1 and SA192?
SA192 is a low-carbon (0.06–0.18% C) seamless boiler tube controlled by hardness, with no tension test. SA210 A-1 is a medium-carbon (0.27% C max) seamless tube with a mandatory 415 MPa tensile requirement, so it permits a thinner wall for the same design pressure.
How are SA210 tube tolerances specified?
Dimensional tolerances come from the general-requirements specification ASTM A450 / ASME SA450 and depend on whether the tube is hot finished or cold finished. SA210 is a minimum-wall specification, so the wall may be over the ordered minimum but not under it.
This is a summary for reference only. ASTM A210/A210M and ASME SA-210 are copyrighted standards; the purchased standard and the edition on the order govern.